We have a product installer created with Wix, containing a program package ("V1") and some configuration files. Now, we are going to make a major upgrade with a new product code, where the old version of the product is uninstalled and "V2" is installed. What we want is to save one of the configuration files from uninstalling, since it is needed for the V2, too. Unfortunately, we forgot to set the Permanent="yes"
option when we delivered V1 (read this question for more information).
Here comes the question: is there an easy way of preventing the uninstall of the file anyhow? Of course, we could add a custom action to the script to backup the file before uninstallation, and another custom action to restore it afterwards, but IMHO that seems to be overkill for this task, and might interfere with other parts of the MSI reg开发者_运维技巧istration process.
EDIT: And yes, the NeverOverwrite="yes"
attribute is already set in V2, and the behaviour is as I described it.
I don't think it will help to change something directly in the component parameters of V2. Perhaps there's a chance to modify the registry somehow in a custom action before uninstalling V1 so the installer service thinks the configuration file in V1 was installed with Permanent="yes"
?
Try the NeverOverwrite
attribute for the configuration file
If this attribute is set to 'yes', the installer does not install or reinstall the component if a key path file or a key path registry entry for the component already exists.
EDIT
I have just tested this in a test setup. At first it didn't work because I had scheduled the RemoveExistingProducts
action before InstallInitialize
sequence. This removes the old product before the new product is installed so it can't compare.
However when I set it to after InstallFinalize
it did work, it left the file there even though the original setup didn't have NeverOverwrite
set. here are my two test examples
version 1.0.0.0
<?xml version="1.0" encoding="utf-8"?>
<Wix xmlns="http://schemas.microsoft.com/wix/2006/wi">
<Product Id="35d07bf8-a729-402d-83d6-fdc55799a3d5" Language="1033" Manufacturer="..." Name="test1" UpgradeCode="9773a278-068d-4fac-8241-4a5b7e54f15a" Version="1.0.0.0">
<Package Compressed="no" InstallerVersion="200" />
<Property Id="ALLUSERS" Value="1" />
<Upgrade Id="9773a278-068d-4fac-8241-4a5b7e54f15a">
<UpgradeVersion OnlyDetect="no" Property="REMOVEOLDVERSION" Maximum="1.0.0.0" IncludeMaximum="no" />
<UpgradeVersion OnlyDetect="yes" Property="NEWERFOUND" Minimum="1.0.0.0" IncludeMinimum="no" />
</Upgrade>
<Directory Id="TARGETDIR" Name="SourceDir">
<Directory Id="ProgramFilesFolder" Name="ProgramFilesFolder">
<Directory Id="INSTALLDIR" Name="test1">
<Component Id="New_Text_Document.txt" Guid="{CCA38D83-A890-4528-B11D-DA2E2DCDED93}" Feature="ProductFeature">
<File Id="New_Text_Document.txt" KeyPath="yes" Source="Harvest\ProgramFilesFolder\INSTALLDIR\New Text Document.txt" />
</Component>
</Directory>
</Directory>
</Directory>
<Feature Id="ProductFeature" Level="1" Title="CompletePackage" Description="The complete Product." Display="expand" />
<CustomAction Id="NewerFound" Error="A later version of [ProductName] is already installed" />
<InstallExecuteSequence>
<Custom Action="NewerFound" After="FindRelatedProducts">NEWERFOUND</Custom>
<RemoveExistingProducts After="InstallFinalize" />
</InstallExecuteSequence>
<UIRef Id="WixUI_Minimal" />
<Media Id="1" />
<UI />
</Product>
</Wix>
version 1.0.1.0
<?xml version="1.0" encoding="utf-8"?>
<Wix xmlns="http://schemas.microsoft.com/wix/2006/wi">
<Product Id="1da36626-d760-4c4c-8a5c-3eb3841dbfd5" Language="1033" Manufacturer="..." Name="test1" UpgradeCode="9773a278-068d-4fac-8241-4a5b7e54f15a" Version="1.0.1.0">
<Package Compressed="no" InstallerVersion="200" />
<Property Id="ALLUSERS" Value="1" />
<Upgrade Id="9773a278-068d-4fac-8241-4a5b7e54f15a">
<UpgradeVersion OnlyDetect="no" Property="REMOVEOLDVERSION" Maximum="1.0.1.0" IncludeMaximum="no" />
<UpgradeVersion OnlyDetect="yes" Property="NEWERFOUND" Minimum="1.0.1.0" IncludeMinimum="no" />
</Upgrade>
<Directory Id="TARGETDIR" Name="SourceDir">
<Directory Id="ProgramFilesFolder" Name="ProgramFilesFolder">
<Directory Id="INSTALLDIR" Name="test1">
<Component Id="New_Text_Document.txt" Guid="{CCA38D83-A890-4528-B11D-DA2E2DCDED93}" Feature="ProductFeature" NeverOverwrite="yes">
<File Id="New_Text_Document.txt" KeyPath="yes" Source="Harvest\ProgramFilesFolder\INSTALLDIR\New Text Document.txt" />
</Component>
</Directory>
</Directory>
</Directory>
<Feature Id="ProductFeature" Level="1" Title="CompletePackage" Description="The complete Product." Display="expand" />
<CustomAction Id="NewerFound" Error="A later version of [ProductName] is already installed" />
<InstallExecuteSequence>
<Custom Action="NewerFound" After="FindRelatedProducts">
NEWERFOUND</Custom>
<RemoveExistingProducts After="InstallFinalize" />
</InstallExecuteSequence>
<UIRef Id="WixUI_Minimal" />
<Media Id="1" />
<UI />
</Product>
</Wix>
The way I am fixing this is very simple. I don't install yourapp.config files but only yourapp.config.new On the first run the application before doing anything else check for the config file. If there is none make a copy yourapp.config.new to yourapp.config
This is very simple it doesn't use any special attributes. When the application is uninstalled the config file is not uninstalled. When the application is re-installed file is disturbed. Note that when the application is repaired the config is not modified either.