I have saved a dataset in the sql database in an xml column using the following code.
XmlDataDocument dd = new XmlDataDocument(dataset);
and passing this xml document as sql parameter using
param.value = new XmlNodeReader(dd);
The XML is like
<NewDataSet><SubContractChangeOrders><AGCol>1</AGCol><SCO_x0020_Number>001</SCO_x0020_Number><Contract_x0020_Number>006</Contract_x0020_Number><ContractID>30</ContractID><ChangeOrderID>211</ChangeOrderID><Amount>0.0000</Amount><Udf_CostReimbursableFlag>false</Udf_CostReimbursableFlag><Udf_CustomerCode /><Udf_SubChangeOrderStatus /></SubContractChangeOrders><SubContractChangeOrders><AGCol>2</AGCol><SCO_x0020_Number>002</SCO_x0020_Number><Contract_x0020_Number>006</Contract_x0020_Number><ContractID>30</ContractID><ChangeOrderID>212</ChangeOrderID><Amount>0.0000</Amount><Udf_CostReimbursableFlag>false</Udf_CostReimbursableFlag></SubContractChangeOrders><SubContractChangeOrders><AGCol>3</AGCol><SCO_x0020_Number>001</SCO_x0020_Number><Contract_x0020_Number>111</Contract_x0020_Number><ContractID>87</ContractID><ChangeOrderID>12</ChangeOrderID><Amount>300.0000</Amount></SubContractChangeOrders><SubContractChangeOrders><AGCol>4</AGCol><SCO_x0020_Number>001</SCO_x0020_Number><Contract_x0020_Number>222</Contract_x0020_Number><ContractID>80</ContractID><ChangeOrderID>6</ChangeOrderID><Amount>100.0000</Amount></SubContractChangeOrders><SubContractChangeOrders><AGCol>5</AGCol><SCO_x0020_Number>001</SCO_x0020_Number><Contract_x0020_Number>777</Contract_x0020_Number><ContractID>79</ContractID><ChangeOrderID>5</ChangeOrderID><Amount>200.0000</Amount></SubContractChangeOrders><SubContractChangeOrders><AGCol>6</AGCol><SCO_x0020_Number>001</SCO_x0020_Number><Contract_x0020_Number>786</Contract_x0020_Number><ContractID>77</ContractID><ChangeOrderID>3</ChangeOrderID><Amount>100.0000</Amount></SubContractChangeOrders><SubContractChangeOrders><AGCol>7</AGCol><SCO_x0020_Number>001</SCO_x0020_Number><Contract_x0020_Number>787</Contract_x0020_Number><ContractID>78</ContractID><ChangeOrderID>4</ChangeOrderID><Amount>500.0000</Amount></SubContractChangeOrders><SubContractChangeOrders><AGCol>8</AGCol><SCO_x0020_Number>001</SCO_x0020_Number><Contract_x0020_Number>Con 009</Contract_x0020_Number><ContractID>219</ContractID><ChangeOrderID>78</ChangeOrderID><Amount>9000.0000</Amount></SubContractChangeOrders><SubContractChangeOrders><AGCol>9</AGCol><SCO_x0020_Number>001</SCO_x0020_Number><Contract_x0020_Number>Con 010</Contract_x0020_Number><ContractID>220</ContractID><ChangeOrderID>79</ChangeOrderID><Amount>13000.0000</Amount></SubContractChangeOrders><SubContractChangeOrders><AGCol>10</AGCol><SCO_x0020_Number>001</SCO_x0020_Number><Contract_x0020_Number>Con 012</Contract_x0020_Number><ContractID>222</ContractID><ChangeOrderID>83</ChangeOrderID><Amount>2300.0000</Amount></SubContractChangeOrders><SubContractChangeOrders><AGCol>11</AGCol><SCO_x0020_Number>001</SCO_x0020_Number><Contract_x0020_Number>Con 020</Contract_x0020_Number><ContractID>226</ContractID><ChangeOrderID>86</ChangeOrderID><Amount>5400.0000</Amount></SubContractChangeOrders><SubContractChangeOrders><AGCol>12</AGCol><SCO_x0020_Number>001</SCO_x0020_Number><Contract_x0020_Number>Con 021</Contract_x0020_Number><ContractID>227</ContractID><ChangeOrderID>87</ChangeOrderID><Amount>2300.0000</Amount></SubContractChangeOrders><SubContractChangeOrders><AGCol>13</AGCol><SCO_x0020_Number>001</SCO_x0020_Number><Contract_x0020_Number>Con001</Contract_x0020_Number><ContractID>208</ContractID><ChangeOrderID>72</ChangeOrderID><Amount>3000.0000</Amount></SubContractChangeOrders><SubContractChangeOrders><AGCol>14</AGCol><SCO_x0020_Number>001</SCO_x0020_Number><Contract_x0020_Number>Con002</Contract_x0020_Number><ContractID>209</ContractID><ChangeOrderID>73</ChangeOrderID><Amount>400.0000</Amount></SubContractChangeOrders><SubContractChangeOrders><AGCol>15</AGCol><SCO_x0020_Number>001</SCO_x0020_Number><Contract_x0020_Number>Con003</Contract_x0020_Number><ContractID>210</ContractID><ChangeOrderID>74</ChangeOrderID><Amount>6000.0000</Amount></SubContractChangeOrders><SubContractChangeOrders><AGCol>16</AGCol><SCO_x0020_Number>001</SCO_x0020_Number><Contract_x0020_Number>Con004</Contract_x0020_Number><ContractID>211</ContractID><ChangeOrderID>75</ChangeOrderID><Amount>9000.0000</Amount></SubContractChangeOrders><SubContractChangeOrders><AGCol>17</AGCol><SCO_x0020_Number>001</SCO_x0020_Number><Contract_x0020_Number>Con005</Contract_x0020_Number><ContractID>213</ContractID><ChangeOrderID>76</ChangeOrderID><Amount>17000.0000</Amount></SubContractChangeOrders><SubContractChangeOrders><AGCol>18</AGCol><SCO_x0020_Number>001</SCO_x0020_Number><Contract_x0020_Number>Cont001</Contract_x0020_Number><ContractID>228</ContractID><ChangeOrderID>89</ChangeOrderID><Amount>2000.0000</Amount></SubContractChangeOrders><SubContractChangeOrders><AGCol>19</AGCol><SCO_x0020_Number>001</SCO_x0020_Number><Contract_x0020_Number>PUR001</Contract_x0020_Number><ContractID>229</ContractID><ChangeOrderID>88</ChangeOrderID><Amount>1000.0000</Amount></SubContractChangeOrders><SubContractChangeOrders><AGCol>20</AGCol><SCO_x0020_Number>001</SCO_x0020_Number><Contract_x0020_Number>PUR002</Contract_x0020_Number><ContractID>230</ContractID><ChangeOrderID>90</ChangeOrderID><Amount>3000.0000</Amount></SubContractChangeOrders><SubContractChangeOrders><AGCol>21</AGCol><SCO_x0020_Number>001</SCO_x0020_Number><Contract_x0020_Number>SC-002</Contract_x0020_Number><ContractID>2</ContractID><ChangeOrderID>7</ChangeOrderID><Amount>200.0000</Amount></SubContractChangeOrders><SubContractChangeOrders><AGCol>22</AGCol><SCO_x0020_Number>001</SCO_x0020_Number><Contract_x0020_Number>SC-004</Contract_x0020_Number><ContractID>7</ContractID><ChangeOrderID>65</ChangeOrderID><Amount>1000.0000</Amount></SubContractChangeOrders></NewDataSet>
I'm trying to read it back as follows
using (SqlConnection con = new SqlConnection("Server=#####;Initial Catalog=#####;User ID=####;Pwd=########"))
{
using (SqlCommand com = new SqlCommand("select * from dbo.tbl_#####", con))
{
using (SqlDataAdapter ada = new SqlDataAdapter(com))
{
ada.Fill(dt);
MemoryStream ms = new MemoryStream();
object contractXML1 = dt.Rows[0]["SCOXML1"];
System.Runtime.Serialization.Formatters.Binary.BinaryFormatter bf = new System.Runtime.Serialization.Formatters.Bi开发者_Python百科nary.BinaryFormatter();
bf.Serialize(ms, contractXML1);
ms.Seek(0, SeekOrigin.Begin);
ds.ReadXml(ms);
}
}
}
I'm getting the following error
Data at the root level is invalid. Line 1, position 6.
Any ideas?
Update
I changed the code to the following. I'm able to get the structure of the dataset with all the tables added inside it. But not the data.
using (SqlConnection con = new SqlConnection("Server=###;Initial Catalog=####;User ID=###;Pwd=######"))
{
using (SqlCommand com = new SqlCommand("select * from dbo.tbl_####", con))
{
using (SqlDataAdapter ada = new SqlDataAdapter(com))
{
ada.Fill(dt);
MemoryStream ms = new MemoryStream();
object contractXML1 = dt.Rows[0]["SCOXML1"];
object schema = dt.Rows[0]["xmlSchemaHistory"];
XmlSerializer xs = new XmlSerializer(typeof(object));
xs.Serialize(ms, contractXML1);
ms.Position = 0;
xDoc.Load(ms);
xDocSc.LoadXml(schema.ToString());
ds.ReadXmlSchema(new XmlNodeReader(xDocSc));
ds.ReadXml(new XmlNodeReader(xDoc));
}
}
}
But the underlying xml document is having the data. Any ideas?
NLV
Why are you using the Binary Formatter? In fact, why are you serializing at all? Isn't your XML column using the SQL Server XML data type? If so, then you need to retrieve the data using the SqlXml
data type.
I've never worked with XML columns and DataTables before. I generally use SqlDataReader
for this purpose. However, I can give you a hint: once you've got an SqlXml
object, you can get the XmlReader
out of it. Once you've got an XmlReader
, you can do:
DataTable dt = new DataTable("tableName");
dt.ReadXml(xmlReader);
See "ReadXml(XmlReader)" and "SqlXml.CreateReader Method".
This is a shot in the dark, but your XML may have a byte order marker (BOM) in your XML, and the binary formatter can't deal with it properly without specifying the encoding. If that's the case, then you may have to load your XML into an encoded stream first.
精彩评论